The Edwards SAPIEN 3 transcatheter heart valve, model 9600TFX, and accessories are indicated for relief of aortic stenosis in patients with symptomatic heart disease due to severe native calcific aortic stenosis who are judged by a Heart Team, including a cardiac surgeon, to be at intermediate or greater risk for open surgical therapy (i.e., predicted risk of surgical mortality ≥ 3% at 30 days, based on the Society of Thoracic Surgeons (STS) risk score and other clinical co-morbidities unmeasured by the STS risk calculator).

Edwards Transcatheter Heart Valves | TAVR by Edwards

Prosthetic Heart Valves | Circulation

Patient Prosthesis Mismatch in the TAVI era | Edwards …

These valves are intended for use in patients whose aortic valvular disease is sufficiently advanced to warrant replacement of their natural valve with a prosthetic one. It is also intended for use in patients with a previously implanted aortic valve prosthesis which is no longer functioning adequately and requires replacement. Valve replacement can include the following risks:

values of aortic valve prosthesis

Prosthesis-patient mismatch (PPM) is associated with increased mid-term and long-term mortality rates after aortic valve replacement (AVR). This study aimed to evaluate the efficacy of the Carpentier-Edwards Perimount Magna and Magna Ease (CEPMs) aortic bioprostheses to reduce the incidence of PPM.

The Edwards SAPIEN 3 transcatheter heart valve and delivery system should not be used in patients who:
The Edwards SAPIEN XT transcatheter heart valve and delivery systems should not be used in patients who:

Starr Edwards Heart Valve Prosthesis | National Museum …

The Edwards SAPIEN XT transcatheter heart valve and accessories are also indicated for patients with symptomatic heart disease due to failure (stenosed, insufficient, or combined) of a surgical bioprosthetic aortic valve who are judged by a heart team, including a cardiac surgeon, to be at high or greater risk for open surgical therapy (i.e., STS operative risk score ≥8% or at a ≥15% risk of mortality at 30 days).

The Edwards SAPIEN 3 transcatheter heart valve and delivery system should not be used in patients who:

TheList_search - MRI Safety Home

The long-term durability of the Edwards SAPIEN XT transcatheter heart valve is not known, at this time. Regular medical follow-up is recommended to evaluate how well a patient’s heart valve is performing.

The Edwards SAPIEN XT transcatheter heart valve and delivery systems should not be used in patients who:

Welcome to the Australian Dental Prosthetists …

N2 - Background and aim of the study: The study aim was to update an analysis of the long-term survival of heart valve replacement using the Starr-Edwards prosthesis. Methods: Cases of isolated aortic (AVR, n = 2,247) and mitral (MVR, n = 1,406) valve replacement with Starr-Edwards prostheses implanted between 1960 and 1997, with follow up to 2003, were reviewed. Introduced in 1965, the Models A1200/1260, M6120 are still in use (Current), while other models have been discontinued (Discontinued). For AVR, 938 valves were Discontinued, with a total follow up of 8,506 patient-years (pt-yr) and a maximum of 41 years; by comparison, 1,309 valves were Current, with a total follow up of 11,586 pt-yr and a maximum of 36.1 years. For MVR, 635 valves were Discontinued, with a total follow up of 6,454 pt-yr and maximum of 37.2 years; and 771 valves were Current, with a total follow up of 6,211 pt-yr and maximum of 37.0 years. Results: Kaplan-Meier (KM) survival at 10 years was 53% for AVR and 51% for MVR; KM survival at 20 years was 23% for both AVR and MVR; KM survival at 30 years was 8% for both AVR and MVR; KM sur-vival at 40 years was 4% for AVR. The standard error for all KM percentages was 1%. Four patients are cur-rently alive with their original valves, more than 40 years after implantation. Conclusion: This series of patients, who underwent valve replacement with the Starr-Edwards valve, now have a follow up extending beyond 40 years, thereby confirming the excellent durability of this valve.